AURORA Inverters INSTALLATION AND OPERATOR’S MANUAL Model number: PVI-3600-OUTD-UK-F-W Rev. 1.0
Installation and Operator’s Manual Page 10 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 2.1 Main Elements of a Wind System: A wind system is
Installation and Operator’s Manual Page 11 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) The Aurora Wind Inverter is designed to accept only a
Installation and Operator’s Manual Page 12 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 2.2 Data Transmission and Check In case multiple inv
Installation and Operator’s Manual Page 13 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) DC/DC Boost ConverterGrid Interface InverterGate Drive
Installation and Operator’s Manual Page 14 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) This process ensures optimal performance levels of the
Installation and Operator’s Manual Page 15 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Control of the internal temperatures to automatical
Installation and Operator’s Manual Page 16 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) WARNING: The connection of AURORA to the electrical d
Installation and Operator’s Manual Page 17 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 3.2 Package Check List Description Quantity (No.) Wind
Installation and Operator’s Manual Page 18 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 3.3 Choosing Installation Location The location for th
Installation and Operator’s Manual Page 19 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 3.4 Wall Mounting AURORA should be mounted in a verti
Installation and Operator’s Manual Page 2 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) REVISION TABLE Document Revision Author Date Change
Installation and Operator’s Manual Page 20 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Install the expansion screws in the wall so that the h
Installation and Operator’s Manual Page 21 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) higher than + 40 °C an output power de-rating may occ
Installation and Operator’s Manual Page 22 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 3.5 Preliminaries to Electrical Connections WARNING
Installation and Operator’s Manual Page 23 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) AURORA to the grid. Recommended ratings for the Ac ove
Installation and Operator’s Manual Page 24 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) WARNING: All power wires connecting to AURORA inverter
Installation and Operator’s Manual Page 25 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) WARNING: Use listed watertight conduit connectors to
Installation and Operator’s Manual Page 26 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) The conduit and the wire lengths depend on the dis
Installation and Operator’s Manual Page 27 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Step 1/7: Open the Ac disconnect switch or circuit br
Installation and Operator’s Manual Page 28 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Step 5/7: Connect AURORA to the Ac disconnect switch
Installation and Operator’s Manual Page 29 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Fig.14: Wind Input with the two input sections para
Installation and Operator’s Manual Page 3 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) IMPORTANT SAFETY INSTRUCTIONS This manual contains im
Installation and Operator’s Manual Page 30 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 2) Install suitable watertight connectors to the AUR
Installation and Operator’s Manual Page 31 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 4 START-UP NOTE: do not lay any object on AURORA durin
Installation and Operator’s Manual Page 32 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 5 MONITORING AND DATA TRANSMISSION 5.1 User’s Inter
Installation and Operator’s Manual Page 33 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Fig. 15 Data Transmission Options
Installation and Operator’s Manual Page 34 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 5.2 Available Data AURORA provides two sets of data th
Installation and Operator’s Manual Page 35 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) All data are available for transmission via the RS-485
Installation and Operator’s Manual Page 36 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) LEDs Status Operational Status Remarks 1 Power (Gr
Installation and Operator’s Manual Page 37 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) G Y R 1) Sleep Mode AURORA is in the disconnectio
Installation and Operator’s Manual Page 38 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) reset, there could be a water seepage due to condensat
Installation and Operator’s Manual Page 39 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Message Warning Type Error Type Description Wind Low
Installation and Operator’s Manual Page 4 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) USEFUL INFORMATION AND SAFETY STANDARD FOREWORD The
Installation and Operator’s Manual Page 40 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 5.5 LCD Display The 2-line LCD display is located on
Installation and Operator’s Manual Page 41 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) This screen shows the grid frequency and the relate
Installation and Operator’s Manual Page 42 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Fourth screen: Output power and Voltage Input
Installation and Operator’s Manual Page 43 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Sixth screen: Time during which the unit exported e
Installation and Operator’s Manual Page 44 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) This screen shows the code of the error found, for
Installation and Operator’s Manual Page 45 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) The sequence of the screens is summarized in the follo
Installation and Operator’s Manual Page 46 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) The values that can be displayed on the previous scree
Installation and Operator’s Manual Page 47 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 6 DATA CHECK AND COMMUNICATION 6.1 RS-485 serial li
Installation and Operator’s Manual Page 48 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) from OFF to ON. The default position of the switch is
Installation and Operator’s Manual Page 49 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 6.2 Power Line Modem (PLM) A PLM modem card is an ava
Installation and Operator’s Manual Page 5 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) In particular, during transport and handling, parts sha
Installation and Operator’s Manual Page 50 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) NOTE: the maximum number of inverters that can be conn
Installation and Operator’s Manual Page 51 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 6.3 Display menù When using PLM or the RS-485 serial
Installation and Operator’s Manual Page 52 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 4) Confirm the choice by pressing once more the k
Installation and Operator’s Manual Page 53 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 2) Verify that the inverter is set in mode Parallel:
Installation and Operator’s Manual Page 54 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 6) Press the key for longer than 5 sec. to confirm th
Installation and Operator’s Manual Page 55 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Resolution Data Display Measurement Accuracy Vin1 1V
Installation and Operator’s Manual Page 56 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 7 TROUBLESHOOTING AURORA inverters comply with standar
Installation and Operator’s Manual Page 57 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Before contacting the service center, keep the followi
Installation and Operator’s Manual Page 58 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 8 TECHNICAL FEATURES 8.1 Input Values WARNING: The
Installation and Operator’s Manual Page 59 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) Description Value PVI-3600-OUTD-UK-F-W Nominal input
Installation and Operator’s Manual Page 6 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) PVI-3600-OUTD-UK-F-W This document applies to the ab
Installation and Operator’s Manual Page 60 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 8.2 Output Values Description Value PVI-3600-OUTD-UK-
Installation and Operator’s Manual Page 61 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 8.4 General characteristics Description Value PVI-3
Installation and Operator’s Manual Page 62 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 8.5 Power Derating To ensure inverter safe operation u
Installation and Operator’s Manual Page 63 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) The above cases, originating a power derating, can als
Installation and Operator’s Manual Page 7 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) CONTENTS: 1 FOREWORD 9 1.1 WIND ENERGY 9 2 SYSTEM D
Installation and Operator’s Manual Page 8 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 8.2 Output Values 60 8.3 Grid protection characteris
Installation and Operator’s Manual Page 9 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) 1 FOREWORD This document contains a technical descripti